Those aren’t supposed to be round on top.

  • Canonical_Warlock@lemmy.dbzer0.com
    link
    fedilink
    English
    arrow-up
    2
    ·
    edit-2
    5 hours ago

    Yeah, testing caps is also a pretty regular part of our PM process. Especially because that one looks like it may partially be a run cap and a system can often run perfectly fine without a run cap except it will cause the motor to pull higher amps and run hotter. Catching a bad run cap early is the difference between replacing a bad cap and replacing a burned up motor.

    Edit: Although you’re already doing far more for your system than most. I’m an actual tech and it’s been a shamefully long time since my equipment at home has had a full PM done.

    • rumba@lemmy.zipOP
      link
      fedilink
      English
      arrow-up
      1
      ·
      55 minutes ago

      That’s good to hear, thanks for that. Yes it’s a dual cap. I’ll have to dig out my LC meter and add that to my list.

      It was a new build, my old plays I didn’t stay on top of things and ended up paying for it. I decided to do a better job here.

      My very first maintenance I went down to look at what I needed to do. It’s a trane unit, so the evaporator coil and the condensate pan come out on a slide which is pretty fancy. The condensate line, combustion and exhaust air are all PVC and they glued it all so you couldn’t get the tray out. (The air lines don’t even go into the box they just ran it past the front for spite I think)

      Hope you don’t mind if I ask you two questions, not holding you accountable or anything.

      What are you guys using for condenser coil cleaner? I just got some off-the-shelf home Depot stuff but it looks sus. I pulled the case and separated the coils out at the two-year mark and followed the instructions on the cleaner. I didn’t see any physical dirt anywhere and there’s no leaves or debris. Without physical dust dirt or debris do you think just hosing it down from the outside on PM is fine?